Why Choose Ventas VHRV Heat Recovery Ventilation Units?
·High Efficiency, Low Energy Consumption
Our advanced heat exchanger technology minimizes energy losses and delivers maximum energy savings.
·Quiet & Comfortable Operation
Low-noise fans and sound-insulated casing ensure a peaceful indoor environment, even during peak performance.
·Wide Product Range
Available in multiple capacities and configurations to suit residential, commercial, and industrial applications.
·ErP-Compliant & Eco-Friendly
Fully compliant with European Ecodesign (ErP) directives and ideal for green building projects.
·Plug & Play Design
Pre-configured and factory-tested systems allow for fast installation and commissioning.
·Smart Control Options
Fully compatible with modern building automation systems (Modbus, BACnet).
·Optional Accessories
Customize your solution with , pre-heaters, electric or water coils, DX coils, CO₂ sensors, humidity controls, and more.
·Low Maintenance, Long Lifespan
Durable components, easy-access service panels, and long-life filters reduce maintenance costs and extend product life.
VENTASTAR VHRV-P Models
Medium Efficient Heat Recovery Units with AC/EC Fan, Horizontal/Vertical Type
•Casing is made of painted galvanized sheets, single skin panel structure with 10 mm nfaf insulation provides heat and noise insulation. Service doors allow easy access to internal components.
•Provides energy savings with cross flow aluminium air to air heat exchangers comply with standard EN 308 and are Eurovent certified.
•AC/EC plug-fan technology provides stepped or proportional speed control.
•G4 minipleat filter class performances are according to EN 779:2012 and ISO 16890 standards, and filters are Eurovent certified.
•Bypass module is optional.
•Condensation pan is available and drain connection is on the bottom of the units.
•Wide capacity range allows design variety
•Equipped with Ventastar Control Unit which allows operation with various scenarios and is compatible with BMS.
•Low noise levels allow comfortable operation in indoor zones.
VENTASTAR VHRV-PLUS Models
Medium Efficient Double Skin Heat Recovery Units with Integrated Coil
•Casing is made of steel and painted steel sheets are used. Double skin panel structure with 60 mm Rockwool (density:110 kg/m3) insulation provides heat and noise insulation. Hinged service doors allow easy access to internal components.
•Double skin construction provides ability to locate heating coil and/or cooling coil and/or DX coil inide of the unit.
•Provides energy savings with cross flow aluminium air to air heat exchangers comply with standard EN 308 and are Eurovent certified.
•High efficient EC plug-fan technology provides propotional speed control.
•G4 minipleat filter class performances are according to EN 779:2012 and ISO 16890 standards, and filters are Eurovent certified.
•Condensation pan is available and drain connection is on the bottom of the units.
•Wide capacity range allows design variety.
•Equipped with Ventastar Controller which allows operation with various scenarios and is compatible with BMS.
•Low noise levels allow comfortable operation in indoor zones.
VENTASTAR VHRV-DX Models
Double Skin Heat Recovery Units with DX Heat Pump
•VENTAS Heat Recovery Units with DX Heat Pump models are designed to provide high indoor air quality by saving energy and meeting required comfort conditions. The units include complete cooling circuit and is reversible.
•Casing is made of steel and painted steel sheets are used. Double skin panel structure with 60 mm Rockwool
(density:110 kg/m3) insulation provides heat and noise insulation. Hinged service doors allow easy access to internal components.
•Provides energy savings with cross flow aluminium air to air heat exchangers comply with standard EN 308 and are Eurovent certified.
•High efficient EC plug-fan technology provides propotional speed control.
•G4 minipleat filter class performances are according to EN 779:2012 and ISO 16890 standards, and filters are Eurovent certified.
•Units with non inverter compressors allow constant speed control for cooling circuits. Units with inverter compressors allow proportional speed control for cooling circuits.
•Condensation pan is available and drain connection is on the bottom of the units.
•Wide capacity range allows design variety.
•Equipped with Ventastar Controller which allows operation with various scenarios and is compatible with BMS.
•Low noise levels allow comfortable operation in indoor zones.
VENTASTAR VHRV-C Models
High Efficient Double Skin Heat Recovery Units with Counterflow Heat Exchanger
•Casing is made of steel and painted steel sheets are used. Double skin panel structure with 60 mm Rockwool (density:110 kg/m3) insulation provides heat and noise insulation. Service doors allow easy access to internal components.
•Provides energy savings with high efficiency hexagonal aluminium air to air heat exchangers comply with standard EN 308
and are Eurovent certified.
•High efficiency EC plug-fan technology complies the ErP2018 requirements and provides proportional speed control.
•M5 and F7 minipleat filter class performances are according to EN 779:2012 and ISO 16890 standards.
•Bypass module is available.
•Condensation pan is available and drain connection is on the bottom of the units.
•Wide capacity range allows design variety.
•Equipped with Ventastar Controller which allows operation with various scenarios and is compatible with BMS.
•Low noise levels allow comfortable operation in indoor zones.
VENTASTAR VHRV-R Models
High Efficient Double Skin Heat Recovery Units with Rotary Heat Exchanger
•Casing is made of steel and painted steel sheets are used. Double skin panel structure with 60 mm Rockwool(density:110 kg/m3) insulation provides heat and noise insulation.
•Provides energy savings with high efficiency hexagonal aluminium air to air heat exchangers comply with standard EN 308 and are Eurovent certified.
•High efficiency EC plug-fan technology complies the ErP2018 requirements and provides proportional speed control.
•M5 and F7 filter class performances are according to EN 779:2012 and ISO 16890 standards.
•Condensation pan is available and drain connection is on the bottom of the units.
•Units with non inverter compressors allow constant speed control for cooling circuits. Units with inverter compressors
allow proportional speed control for cooling circuits.
•Equipped with Ventastar Controller which allows operation with various scenarios and is compatible with BMS.
Optional Accessories
•Duct Type Electric Heater
•Duct Type Heating Coil
•Duct Type Cooling/DX Coil
•Duct Type Silencer
•F7 Filter
•Active Carbon Cartridge Filter
•Hepa Filter
•Flexible Connection
•Motorized Damper
•Differential Pressure Switch
•CO2 / VOC Sensor
•Door Switch
•Frost Thermostat