• Double Walled Chimney Systems ADL DW
  • ADL DW is an insulated chimney type that should be used in case the heat conditions cannot be met in chimney operating conditions.
  • The system is double walled. All surfaces in contact with the waste gas are made of AISI 316 L stainless steel. The outer walls, on the other hand, can be manufactured from AISI 304 (DW) or AISI 430 (ekoDW) stainless steel with a minimum thickness of 0,40mm with glossy BA coating, depending on the request and project conditions.
  • 25 mm or 50 mm thick rockwool is used as insulation material between the two walls. Rockwool is placed between the inner and outer walls in a continuous and tight structure up to the muff part of the module. Thus, since the inner and outer walls are connected to each other, the static and mechanical strength of the chimney increases. Since metal fasteners are not used between the two walls of the chimney, a homogeneous thermal insulation is provided from the boiler flue connection to the chimney cap without creating thermal bridges.
  • The system is designed to compensate for thermal expansions within itself.
  • Since the flue gas temperature passing through the system is not transmitted to the outside environment, the condensation rate is low, the chimney efficiency and fuel savings are high.
  • Chimney components cut on special CNC benches are combined with continuous TIG and LASER welding technology. Thanks to the special bell structure in the chimney connections, the elements that make up the chimney are connected to each other in a way that provides perfect condensation water and waste gas tightness.
  • The muf (female/male) system, which is in different directions on the outer and inner walls, provides perfect insulation and waterproofing, and guarantees that the product performance and mechanical properties are preserved unchanged over the years.
  • Thanks to the external connection clamps used at the joints, tightness and strength are maximized.
  • The product can also respond to aesthetic needs with painted or outer copper models in the desired RAL code according to the customer's request.
  • Double-walled chimney systems should be used in all cases where flue gas temperature conditions are not met and unintentional touch temperature standards cannot be complied with in the section calculations made according to EN 13384 -1 and -2.

Double Wall Chimney System

HS Code : 730890

Certificates : certificate certificate

Product Details

Technicial Specifications

Other products

About the Company

Contact

Usage areas

Heating and hot water boilers

Atmospheric, blown burner or condensing boiler systems

Solid, liquid and gas fired boiler systems

Steam and hot oil boilers

Wood stoves

Fireplaces

Pellet stoves

In-shaft flue systems

Cascade chimney systems

Chimney renovation operations

Industrial or domestic kitchen hoods

Ventilation systems

Waste gas systems of process devices

Outdoor chimney systems

Industrial plants, rolling mills, melting pots

Process and hood systems through which high temperature flue gas passes

Ram machines, textile industry

Paint and drying ovens


Features

Production with TIG and LASER welding technology

0.4mm – 2.00mm inner wall sheet thickness

Outer wall sheet thickness between 0.4mm- 0.8mm

25mm or 50mm insulation thickness

Standard production in diameters between Ø80mm – Ø1200mm

V2 corrosion resistance

Suitable for N1-P1-H1 systems

Resistance to soot fire

50mm special sealed structure


Advantages

Use in accordance with standards in different fuel types (solid, liquid, natural gas)

Quick and easy assembly

100% sealing with special structure

High efficiency is ensured thanks to low thermal permeability

Use in accordance with standards in different pressure classes N1 – P1- H1

Use in accordance with standards in different operating types D and W

Resistance to soot fire

Long life thanks to V2 corrosion resistance

Produces economical and aesthetic solutions thanks to different outer wall options