FANMAK Air Conditioning Units are manufactured as standard in 18 different sizes with flow rates between 1,500 m3 / h and 100,000 m3h upon request. Shopping mall, hospital, factory, cinema, hotel, school, pharmaceutical, warehouse, printing house, restaurant, office, cafe, industry etc. plants are used for ventilation, heating, cooling and humidification.
BODY STRUCTURE As standard; 50 mm panel thickness, 52 kg / m3 or 72 kg / m3 density Air Conditioner power plant module structure edge profiles, reinforcement profiles and corner elements of the skeletal structure used to cover the 6 sides of the cover panels are manufactured from galvanized sheet sandwich structure. Stone wool material is in the middle part. Total panel thickness is 30 mm or 50 mm. REINFORCEMENT PROFILES In the module structure of air handling units, reinforcement profiles used to reinforce the connections between the edge profiles and the covers of different cells of the device are obtained from aluminum material. In order to minimize the pressure losses in the plant, all internal profile surfaces are closed. EDGE PROFILE The edge profiles that form the outer frame in the module structure of the air handling units are made of aluminum material. In order to minimize the pressure losses in the plant or to prevent any accumulation of dirt, the profile inner surfaces are completely closed. Its manufacturing is compatible with corner elements. CORNER ELEMENTS The corner elements used to provide edge profiles corner joints in the module structure of air handling units are made of aluminum material by injection. Thanks to the compatibility of the edge profiles in the design of the corner elements, possible air leaks and image defects are prevented.SEALING GASKET The sealing gaskets are made of EPDM material with air cushion. It does not deform and provides contact with all surfaces thanks to airbags. DOOR HANDLES AND LOCK MECHANISM It is made of hard PVC material in order to keep the service covers mentioned in the outer panels section closed or to open them easily. HINGES The hinges used for the movable mounting of the service covers mentioned in the outer panels section are made of rigid PVC material. Hinges are used as 2, 3 or 4 pieces per service cover depending on the height of the device. AIR DAMPER It consists of air dampers used for air adjustment and air circulation in air handling units, damper wing profiles made of aluminum material, gear and bearing evening made of rigid PVC material and outer body made of aluminum. Gear and bearing mechanisms are assembled and mounted in such a way that they do not allow any stripping or pinching. INTERNAL STRUCTURE VENTILATOR AND ASPIRATOR UNITS Ventilator / aspirator units in air handling units are manufactured in standard cell structure with static and dynamic balancing. Fans and aspirators are high efficiency, radial double suction fans with forward curved blades, statically and dynamically balanced. MOTORS Electric motors are three-phase, optionally single-phase. 380V, 50 Hz). The motors are rated IP 54 or 55. HEATER AND COOLER BATTERY UNITS Air handling unit heater and cooler units are manufactured as aluminum wing / copper pipe or steel wing / steel pipe depending on fluid properties and user requests. Copper pipes are available in 3/8 ’, 1/2 * or 5/8” diameters depending on capacity and fluid properties; Steel tube heater / cooler coils are manufactured by using patent or welded black pipe with 16 x 0.5 mm steel tape depending on fluid and capacity characteristics.HEAT RECOVERY UNITS These are the units used to save energy by heating or cooling the exhaust air and fresh air in the air handling units. BAG FILTER UNIT Depending on need, bag filters are used in EUROVENT 4/5 standards in EU 5,6,7,9 classes. Bag filters are assembled using gaskets made of EPDM material for ease of removal and installation. FRONT FILTERING UNIT In air handling units, front filtering unit is manufactured in standard cell structure. Pre-filters are used in EUROVENT 4/5 standards, EU 3-4 class, specially designed zigzag structure. Thanks to its zigzag structure, air velocity of 1.5 m / s on the filter surface is not exceeded. HUMIDIFICATION UNIT Humidification Unit: The humidification unit of the air handling unit is made of 2 mm galvanized sheet. The cell consists of 2 mm DKP sheet bottom pool, water distribution pipes designed according to capacity, sprinklers made of rigid PVC material, main distribution pipe, discharge, overflow and feeding connection openings and sight glass made of rigid PVC material. Steam Humidification Unit: Steam humidification unit of the air handling unit is manufactured in standard cell structure. The device is mounted inside the cell with special designed drop holders made of PVC material. SILENCER UNIT Silencer unit is manufactured in standard cell structure in air handling units. The silencer backdrops are manufactured in 20 cm width by using glass or wool. The two sides of the backstage which come into contact with air are coated with Fibrocam material. SAFETY SWITCH It has been installed so that the unit cannot be switched on via the control panel during maintenance of the Air Handling Unit by authorized personnel.