Optional Features
Condenser fan speed control
Hydrophilic/epoxy coating on evaporator and condenser coil surface
Copper tube, copper wing condensers
Cage protection in air cooled condensers
Models with low noise levels
Units suitable for indoor use with high pressure radial fans
Models with inverter scroll compressors
Flexibility in design and production
Imbat domestic chiller units are designed to cool the utility water in T3 climate areas where the water temperature can be up to 55°C. The units can be used in hotels, gyms, schools, offices, residences and will provide optimum performance with low electric cost. Imbat domestic chiller units are 100% original design to cool the 50°C water down to 26°C and will provide cool utility water to buildings.
The units are designed to operate in an average of 46°C outdoor temperature and have three different capacity options; 14, 26 and 46 kW. They include tank, pump, remote control and plug&play properties. Multiple units can operate together for larger capacity requirements. The domestic chillers have scroll type compressors, low energy and high performance axial condenser fans, stainless plate type exchanger, stainless circulation pump and therefore has low energy consumption.
- T3 climate, 46°C outdoor temperature
- Asymmetrical cooling
- 50°C/26°C cooling utility water
- Plug&Play
- 14-46 kW capacity range
Microprocessor Control
Microprocessor system allows the compressors to age simultaneously in case of partial loads, providing maximum energy efficiency and efficient cooling. The microprocessor settings will not be deleted in case of power cuts and the unit automatically restarts when power is restored.
Asymmetrical Cooling
Asymmetrical cooling circuit is an innovation that connects multiple compressors on same condenser and evaporator circuits. It decreases condensation temperature and increases evaporation temperature, ensuring energy efficiency. This application allows 3 steps capacity control with 2 compressors and will increase efficiency by up to 35% in partial loads. Further, the start-stop action of compressors is decreased by 1/8 ratio with asymmetrical cooling circuit. Cooling units very rarely operate at full capacity. Asymmetrical cooling technology provides energy efficiency in partial loads which is almost always.
Maximum Water Security On Water Side
Pressure difference switch, stainless steel filters, anti-freeze temperature control and electric heaters are precautions for maximum safety in plate type evaporators.