• FREE COOLING CHILLER UNITS.
  • Air-based free cooling uses low-temperature ambient air as a cooling medium for chilled water systems, thus providing significant opportunities to generate energy savings. The more time the chilled water system can operate in the free cooling mode, the greater energy efficiency it can deliver.
  • Although free cooling technology is not new and widely used in many chilled water applications, there are a variety of ways to raise efficiency, including adopting innovative heat exchangers, engaging the partial free cooling operation mode, and the application of advanced methods for free cooling control.
  • FREE COOLING MODES
  • Partial free cooling
  • The key condition to start free cooling operation is when the ambient temperature drops below return water temperature. In conditions such as these, free cooling system tops up the cooling demand by running in parallel with compressors. Ambient temperature monitored continuously to run fans as fast as possible and achieve the maximum free cooling while keeping the compressors within the operating envelope.
  • Full free cooling
  • When the ambient temperature falls enough for a free cooling system to satisfy the overall cooling demand, the compressors switch off, and the system keeps the required water temperatures by regulating the speed of the fans and water flow.
  • Elevated water temperatures
  • Raising chilled water temperatures can generate more free cooling opportunities so that the system will work more hours in free cooling mode, full and partial. In the applications where chilled water temperatures can be lifted without adverse impacts, free cooling technology will provide the constant savings in operational costs.
  • Recent studies have shown that cooling air temperature in data centers can be raised up to 27°C without damaging the electronic equipment or reducing its lifespan. Therefore chilled water temperature can also be elevated in data center applications, thus ensuring significant power savings.
  • Extended operating range
  • The use of air-cooled chillers under cold weather conditions restricted due to refrigeration side limitations. Extreme cold weather is not an issue for free cooling chillers which will continue operation in free cooling mode by regulating fan speed and water flow through the free cooling coils as necessary. In response to temperature changes, water flow regulated automatically by 3-way or 2-way actuated valves, which help to avoid both excessive and minimal flows.
  • Fan speed control
  • Variable fan speed control assists to save the energy by regulating the speed of the fans as required rather than running them at full speed as the ambient temperature falls.
  • Free cooling system by KURUMAN
  • KURUMAN uses the newly developed micro channel heat exchangers that feature increased heat transfer rates and capacity as free cooling coils. With these coils, the temperature at which free cooling system satisfies 100% cooling demand is higher by 4°C compared to the system with traditional fin/tube heat exchangers.
  • Such an increase in free cooling opportunities translates to significant power savings. For example, in Central European climate zone our free cooling chillers enable a saving of up to 250,000 kWh per 1.000 kW of cooling capacity annually.

Packaged Chiller

HS Code : 841869

Certificates : certificate certificate certificate

Product Details

Technicial Specifications

Other products

About the Company

Contact

Air-based free cooling uses low-temperature ambient air as a cooling medium for chilled water systems, thus providing significant opportunities to generate energy savings. The more time the chilled water system can operate in the free cooling mode, the greater energy efficiency it can deliver.

Although free cooling technology is not new and widely used in many chilled water applications, there are a variety of ways to raise efficiency, including adopting innovative heat exchangers, engaging the partial free cooling operation mode, and the application of advanced methods for free cooling control.

FREE COOLING MODES

Partial free cooling

The key condition to start free cooling operation is when the ambient temperature drops below return water temperature. In conditions such as these, free cooling system tops up the cooling demand by running in parallel with compressors. Ambient temperature monitored continuously to run fans as fast as possible and achieve the maximum free cooling while keeping the compressors within the operating envelope.

Full free cooling

When the ambient temperature falls enough for a free cooling system to satisfy the overall cooling demand, the compressors switch off, and the system keeps the required water temperatures by regulating the speed of the fans and water flow.

Elevated water temperatures

Raising chilled water temperatures can generate more free cooling opportunities so that the system will work more hours in free cooling mode, full and partial. In the applications where chilled water temperatures can be lifted without adverse impacts, free cooling technology will provide the constant savings in operational costs.

 

Recent studies have shown that cooling air temperature in data centers can be raised up to 27°C without damaging the electronic equipment or reducing its lifespan. Therefore chilled water temperature can also be elevated in data center applications, thus ensuring significant power savings.

Extended operating range

The use of air-cooled chillers under cold weather conditions restricted due to refrigeration side limitations. Extreme cold weather is not an issue for free cooling chillers which will continue operation in free cooling mode by regulating fan speed and water flow through the free cooling coils as necessary. In response to temperature changes, water flow regulated automatically by 3-way or 2-way actuated valves, which help to avoid both excessive and minimal flows.

Fan speed control

Variable fan speed control assists to save the energy by regulating the speed of the fans as required rather than running them at full speed as the ambient temperature falls.

Free cooling system by KURUMAN

KURUMAN uses the newly developed micro channel heat exchangers that feature increased heat transfer rates and capacity as free cooling coils. With these coils, the temperature at which free cooling system satisfies 100% cooling demand is higher by 4°C compared to the system with traditional fin/tube heat exchangers.

Such an increase in free cooling opportunities translates to significant power savings. For example, in Central European climate zone our free cooling chillers enable a saving of up to 250,000 kWh per 1.000 kW of cooling capacity annually.