Sanica PVC Drainpipe and fittings provide drainage of foundation and indoor's waste waters ideally and safely, without
leakage, for villas and multi-tiered houses, hospitals, schools, hotels, industrial and sports etc. structures to be
ecological and economical and to protect physical structure up to 60°C temperature and long term use.
They would be manufactured at B application class wall thickness which is defined according to TS 275-1 EN 1329-1 quality
standard.
They would not let residue and droppings thanks to their smooth internal and external surfaces, would not let bacterial
reproduction and they are odourless.
Sanica PVC Drainpipes and fittings manufactured from Solid PVC raw material are in hard-combustible building
material class which is defined as B! in DIN 4102 standards and National Fire Regulations. Sanica PVC essential drain
and fittings would not burst into flames in potential fires due to this specification (PP-based products are flammable and
combustible) and would not let the inter-floor passing of fire. Therefore, they would be preferred for multi-tiered
structures in particular.
Sanica PVC Drainpipe and fittings would meet all your waste water discharge requirementsof structures through different
diameters between 50 - 315 mm and sizes between 150 -6000 mm. PVC Drain fittings are definitely leakproof due to single
bearing, nail and full-compatible housing gasket. Installation of draining system can be swiftly done thanks to easy plugging
and unplugging and does not required demanding jobs such as cutting, bending, bonding etc
PVC Pipe and Fittings Specifications
PVC Drainpipe and Fittings Technical Specifications
Related Standards
PVC Drainpipe and fittings are manufactured at B application class wall thickness which is defined according
to TS 275-1 EN 1329-1 quality standard.
Description of Standard
Pipes, fittings and system features
Field of Application Code
B : It covers indoors components to be used on ground or outdoor components mounted on wall.
D : It covers pipes and components used to connect to make a connection with underground drainage and sewerage systems
by burying underground at a 1 meter distance from the building.
BD : It covers both application class components.
PVC Pipes Physical Specifications
1- Vicat Softening Temperature (min. 79° C) (TS EN 727)
2- Longitudinal Size Change (TS EN ISO 2505)- (15 minutes 150°C) ( %5)
3- Resistance to DICHLOROMETHANE at specified temperature (15°C-30 minutes)
PVC Fittings Physical Specifications
1- Vicat Softening Temperature (min. 79°C) (TS EN 727)
2- Heat effect (150°C - 30 minutes)
a) Depth of peelings or blisters, fractures occurred in a space with a radius 15 times more than wall thickness around
injection point should not be more than 50% of wall thickness on that point.
b) Length of fractures occurred in a distance 10 times more than wall thickness of ring housing should not be more than
50% of wall thickness on that point.
c) Space on connection line should not be more than 50% of wall thickness on this line.
d) Depth of peelings on any other area of the piece should not be more than 30% of wall thickness, length of them should
not be more than 10% of wall thickness.
PVC Pipes Mechanical Specifications
Should be in accordance with TS 2171-1 EN 1401-1.
1- Mechanical Resistance or Flexibility (TS EN 12256)
2- Impact Resistance (TS prEN 12061)
PVC Fittings Mechanical Specifications
In accordance with DIN 4102 standards, they would be manufactured from hard-combustible solid PVC raw material, which is
defined at B1 class according National Fire Regulations and at V-0 class according to American UL94 standards.
Sanica solid PVC essential drain and fittings would not burst into flames in potential fires due to its
specification and would not let the inter-floor passing of fire.